久久久久久国产精品无码下_色婷婷精品久久一区综合_久久se精品一区二区国产_91大神精品全国在线观看

PRODUCT

ENTERPRISE BRIEF INTRODUCTION

HKGD-601 Anti Islanding Device

PRODUCT OVERVIEW

The device is suitable for the protection,measurement and control of high And low voltage interval units of new energy power generation at various voltage levels,and has perfect protection,measurement,control and communication monitoring  fundtions,providing a complete solution for the protection and control of new energy power generation systems, which can effectively ensure the safe and stable operation of high and low voltage power grids and plant power systems.

Together with other protection and automation equipment,and automation system,can be formed through communication  interfaces.All devices can be installed centrally on the screen,or installed in the high and low voltage switchgear. At same time,it is widely used in distributed photovoltaic power stations,when the  photovoltaic side or any side of the grid side loses power,the anti-island protection device will quickly issue a command to the grid-connected switch,let it trip,thereby Ensuring the life safety of maintenance personnel on both sides of the photovoltaic,The device has a loss of voltage tripping,detection with pressure automatic closing function,when the fault is lifted,both sides of the photovoltaic are in a normal state.

And the the lone bind protection device will detect the relevant signal.Automatically close the grid-connected switch to make it work normally,eliminatingthe tedium of manual grid-connection

 

KEY FEATURE

  • Shockproof,dustproof,anti-interference
  • RS485,Mod bus communication interface
  • Self testing function
  • Up to 150 event recording
  • All or more functions customizable

 

 

Rated Working Voltage

AC220、DC220V or  DC110V

AC Current

5A or 1A

AC Voltage

400V or 100V

Frequency

50HZ

Working Power Supply

5w≥ when working,10w≥,when protection acting

AC Current Loop

< 1VA/phase (IN =5A);

< 0.5VA/phase (IN =1A)

AC Voltage Loop

< 0.5VA/phase

Accurate Working Rage

 

Current

< 0.5VA/phase

Voltage

0.4V~1.2Un

 

 

 

Frequency

0.9Fn~1.1Fn

Time

0~100s

Protection Accuracy

 

Setting Accuracy

≤±5%

Time Accuracy

<±1% setting time +35ms

Group Action Accuracy

≤35ms

Frequecny Accurty

≤0.01Hz

Measurement & monitoring

Accuracy

 

AC Quantity Accuracy

≤±0.2%

Active & Reactive

≤±0.5%

Switch Input

 

Input Mode

Passive

Optoelectronic Isolation

8

Working Voltage

AC220V, DC220V or DC110V

Open Contact Capacity

 

A) Outlet Relay

 

Touch Point Rated Current

Carring Capacity

250Vac/220Vdc, 5A

Output Mode

Passive (empty contact)

B) Signal Relay

 

Touch Point Rated Current

Carring Capacity

250Vac/220Vdc, 5A

Output Mode

Passive (empty contact)

Communication Contact

 

Quantity

1

Electrical Characteristics

RS485

Transmitting Mode

Asynchronization

 

 

 

Communication Protocol

MOD Bus

Address

1--110

Baud Rate

≤1Mbps

Communication Medium

Twisted pair or fiber

Environment Parameter

 

Insulation Resistance

≥ 100 MΩ

Dielectric Strength

50Hz

Surge Voltage

(1.2/50) μ 5kv

Burst Interference

1MHz and 100kHz

Radiated Electromagnetic

Field Interference

Ⅲ 10V/m

Electrostatic Discharge

Interference

IV  8kV deviation ±5%(touch), 15kv deviation ±5% (air)

Fast Transient Interference

IV  4kV ±10%

Nature Environment

 

Working Temperature

-25℃~70℃

Storage Temperature

-40~+85℃

Humidity

5~95%RH

Mechanical Environment

Ⅰ (shock response)

Ran Sportation Condition

Ⅰ(vibration durability,shock durability,collision)

 

                      

HKGD-601 Anti Islanding Device